+高级检索
结构尺寸对Ti6Al4V多孔结构力学性能的影响
作者:
作者单位:

1.激光工程研究院;2.上海卫星工程研究所

作者简介:

通讯作者:

中图分类号:

TN249

基金项目:

国家自然科学基金资助(项目号51675012)


Unit Cell Size Effect on Mechanical Properties of Ti6Al4V Porous Structure
Author:
Affiliation:

1.Institute for Laser Engineering,Beijing University of Technology;2.Shanghai Institute of Satellite Engineering

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    采用激光选区熔化技术制造了不同单元结构尺寸(1~6 mm)、孔隙率(40~80%)的拓扑优化多孔阵列结构,研究了单元结构尺寸对其压缩形变规律和弹性性能的影响。结果表明,多孔阵列结构的抗压强度、弹性模量均与单元结构尺寸成反比,抗压强度在126~199 MPa,弹性模量在3.5~55.47 GPa;压缩应力-应变曲线与单元结构尺寸有关,分别遵循弹性、弹脆性和脆性多孔材料三种应力应变规律;通过数值模拟多孔阵列结构的压缩形变过程,解释了两种45°断裂带的成因,力学性能与实验结果基本吻合;利用Gibson-Ashby模型评价多孔结构的稳定性,稳定性参数C与单元结构尺寸成反比;给出Gibson-Ashby拟合方程,特征参数n随单元结构尺寸增加而增大;建立了单元结构尺寸、相对密度和相对弹性模量的三维曲面数学模型,提出骨植入体的设计区域。

    Abstract:

    Topology optimized porous lattice structure with different unit cell size (1~6 mm) and porosity (40~80%) were fabricated by Selective Laser Melting, and their compressive deformation behavior and elastic properties were discussed. The results shown that compressive strength and elastic modulus of lattice structure were inversely proportional to unit cell size. Their compressive strength ranged from 126 to 199 MPa and elastic modulus ranged from 3.5 to 55.47 GPa. The stress-strain curves of lattice structures with different unit cell size followed three kinds of stress-strain laws: elastic material, elastic-brittle material and brittle material. The compressive deformation process was simulated by ABAQUS and explained the reason of two 45° fracture band. The numerical results shown a good agreement with experimental results. The stability was evaluated by Gibson-Ashby model, and the stability parameter C decreased with the increase of unit cell size. Meanwhile, the fitting curves based on Gibson-Ashby model were established, and the value of n increased with the increase of unit cell size. A 3D surface mathematical model combining unit cell size, relative density and relative elastic modulus was established, and the design area satisfying mechanical properties of bone implants was proposed.

    参考文献
    相似文献
    引证文献
引用本文

徐仰立,张冬云,胡松涛,陈润平,顾亦磊,陶炯鸣,孔祥森.结构尺寸对Ti6Al4V多孔结构力学性能的影响[J].稀有金属材料与工程,2020,49(5):1736~1742.[Xu Yangli, Zhang Dongyun, Hu Songtao, Chen Runping, Gu Yilei, Tao Jiongming, Kong Xiangsen. Unit Cell Size Effect on Mechanical Properties of Ti6Al4V Porous Structure[J]. Rare Metal Materials and Engineering,2020,49(5):1736~1742.]
DOI:10.12442/j. issn.1002-185X.20190197

复制
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2019-03-10
  • 最后修改日期:2019-04-22
  • 录用日期:2019-05-14
  • 在线发布日期: 2020-06-05
  • 出版日期: