+高级检索
Pb-Co阳极在含氯硫酸电解液中的电化学行为
作者:
作者单位:

1.河北工程大学 材料科学与工程学院,河北 邯郸 056038;2.株洲冶炼集团有限公司,湖南 株洲 412000;3.中南大学 冶金与环境学院,湖南 长沙 410083

作者简介:

通讯作者:

中图分类号:

基金项目:

NSFC(51904085, 51904086 and U20A20272), Zhuzhou Smelter Group Co., Ltd. (ZYKJ20220408003), Natural Science Foundation of Hebei Province (E2021402056), and Science and Technology Research and Development Program of Handan City (21422101235).


Electrochemical Behavior of Pb-Co Anodes in Sulfuric Acid Electrolyte Containing Cl- Ions
Author:
Affiliation:

1.School of Materials Science and Engineering, Hebei University of Engineering, Handan 056038, China;2.Zhuzhou Smelting Group Co., Ltd, Zhuzhou 412000, China;3.School of Metallurgy and Environment, Central South University, Changsha 410083, China

Fund Project:

National Natural Science Foundation of China (51904085, 51904086, U20A20272); Supported by Zhuzhou Smelting Group Co., Ltd (ZYKJ20220408003); Natural Science Foundation of Hebei Province (E2021402056); Science and Technology Research and Development Program of Handan City (21422101235)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    采用粉末冶金法制备了不同Co含量(0.5%,1.0%,2.0%,质量分数)的Pb-Co阳极,并与传统的Pb-Ca-Sn阳极进行了对比试验。通过电化学测试研究了阳极在160 g/L H2SO4、500 mg/L Cl-电解液中的电化学行为,研究了恒电流极化72 h后阳极氧化层的物相组成、表面形貌和元素分布。随着Co含量的增加,Pb-Co阳极的电位、电荷传递电阻和析氧过电位逐渐降低。恒电流极化72 h后,Pb-2%Co阳极的析氧过电位比Pb-Ca-Sn阳极低101 mV。此外,在Cl-的存在下,电荷传递得到改善,析氧反应受到抑制,阳极氧化层恶化。

    Abstract:

    Pb-Co anodes with different Co contents (0.5wt%, 1wt%, and 2wt%) were prepared by powder metallurgy, and the traditional Pb-Ca-Sn anode was used as the reference for comparison. The electrochemical behavior of the anodes in the electrolyte containing 160 g/L H2SO4 and 500 mg/L Cl- ions was evaluated by electrochemical measurements. The phase composition, surface morphologies, and element distribution of the anodic oxide layers after galvanostatic polarization for 72 h were investigated. With increasing the Co content, the anodic potential, charge transfer resistance, and oxygen evolution overpotential of the Pb-Co anodes are decreased gradually. After galvanostatic polarization for 72 h, the oxygen evolution overpotential of Pb-2wt% Co anode is lower than that of Pb-Ca-Sn anode by 101 mV. In addition, due to the presence of Cl- ions, the charge transfer is improved, the oxygen evolution reaction is inhibited, and the oxide layer is deteriorated.

    参考文献
    相似文献
    引证文献
引用本文

王帅,刘颖,徐东,林文军,王勇,赵烁,杨娟,周向阳.Pb-Co阳极在含氯硫酸电解液中的电化学行为[J].稀有金属材料与工程,2023,52(5):1565~1572.[Wang Shuai, Liu Ying, Xu Dong, Lin Wenjun, Wang Yong, Zhao Shuo, Yang Juan, Zhou Xiangyang. Electrochemical Behavior of Pb-Co Anodes in Sulfuric Acid Electrolyte Containing Cl- Ions[J]. Rare Metal Materials and Engineering,2023,52(5):1565~1572.]
DOI:10.12442/j. issn.1002-185X.20220805

复制
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-10-14
  • 最后修改日期:2023-01-06
  • 录用日期:2023-02-14
  • 在线发布日期: 2023-05-31
  • 出版日期: 2023-05-29