+Advanced Search
Non-cyanide Pulse Electroplating Process for Au-Pd-Cu Alloy
DOI:
Author:
Affiliation:

Dalian University of Technology

Clc Number:

TQ153.2

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    A non-cyanide sulfite bath pulse electroplating process for Au-Pd-Cu alloy was investigated. Thinking about the coating’s surface morphology and the plating’s deposition rate, the optimized electroplating parameters were found as follows: current density 0.25A/dm2, duty ratio 10%, pulse frequency 900Hz, temperature 60℃. Tra-depth microscope was used to observe coating’s surface morphology, and X-ray diffraction was used to analyze the phase components. Meanwhile, the coating’s binding force was tested by means of thermal shock test and root bend test.Furthermore, the coating’s hardness was meatured by Vickers. The results showed that there were only Au, Pd and Cu in the coating without any impurity elements and the coating had fine and uniform grains, with high hardness, excellent adhesion, low porosity, good smoothness and free of cracks.

    Reference
    Related
    Cited by
Get Citation

[wangyu, jinzhuji. Non-cyanide Pulse Electroplating Process for Au-Pd-Cu Alloy[J]. Rare Metal Materials and Engineering,2016,45(1):171~176.]
DOI:[doi]

Copy
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 25,2013
  • Revised:January 08,2014
  • Adopted:January 20,2014
  • Online: January 04,2019
  • Published: