Blood Compatibility of TiO2-HA Bioceramic Coating on Titanium
Affiliation:

School of Mechanical Engineering,Jiangsu University,,School of Mechanical Engineering,Jiangsu University,Laboratory Animal Research CenterS,Jiangsu University,Laboratory Animal Research CenterS,Jiangsu University

Clc Number:

R138

  • Article
  • | |
  • Metrics
  • |
  • Reference [16]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    Modified titanium materials, including TiO2 and TiO2-HA bioceramic coatings, were prepared by micro-arc oxidation and micro-arc oxidation-hydro-thermal methods. Determination of the hemocompatibility of the coatings through a hemolysis experiment, dynamic clotting time test, and platelet adhesion experiment was also performed. The results demonstrated that: Hemolysis rates of all samples were less than 5%, no hemolysis was observed. Compared with titanium and TiO2 bioceramic coating of titanium, TiO2-HA bioceramic coating of titanium exhibited lower hemolysis rate, slower change in dynamic clotting time and less platelet adherence. The proposed TiO2-HA bioceramic coating further showed a lower degree of deformation, better inhibition of platelet aggregation and deformation, and excellent hemocompatibility.

    Reference
    [1] Satsangi A, Satsangi N,Glover R et al.Biomaterials[J],2003, 24(25):4585
    [2] Hu Tao(胡涛), Chu Chenglin(储成林), Sun Weibin(孙卫斌) et al. Rare Metal Materials and Engineering(稀有金属材料与工程) [J],2007,36(6): 1074
    [3]Yu S, Yu Z T, Wang G et al. T Nonferr Metal Soc [J], 2011, 21(3):573
    [4] Shao H H, Yu C H, Xu X J et al. Appl Surf Sci [J],2010, 257(5): 1649
    [5] Cui X Y, Kim H M ,SKawashita M et al. J Ceramic Soc Jap[J], 2008, 116(1350):329
    [6] Meirelles L,SArvidsson A,SAndersson M et al. J Biomed Mater Res A[J],2008,87(2):299
    [7] 20140819 Xu Lin(徐琳),Ding Jianning(丁建宁),Xu Xiaojing(许晓静) et al. Analysis of Structure and Surface Energy of Composite Ceramic Coating on TA2 Titanium by Micro-arc Oxidization-Hydrothermal Synthesis. Rare Metal Materials and Engineering(稀有金属材料与工程),2014.10 Accepted
    [8] 20140066 Xu Lin(徐琳),Ding Jianning(丁建宁),Xu Xiaojing(许晓静) et al. Research on wettability and corrosion resistance of ultrafine-grained titanium by micro-arc oxidation. Rare Metal Materials and Engineering(稀有金属材料与工程),2014.03 Accepted
    [9] Owens D K,Wendt R C. J Appl Polym Sci[J],1969,13(8):174
    [10]Huang L Y, Xu K W, Lu J. J Mater Sci Mater Med[J], 2000, 11(11):667
    [11]Sawyer P N.SBiomater Med Dev Artif Organs[J],1984,12(3-4):161
    [12] Bauschmidt P, Schaldach M. J Bioeng [J], 1977, 1: 261-278
    [13] Bauschmidt P, Schaldach M. Med Bio Eng Comput[J],1980, 18(4): 496
    [14]Zhang Feng(张峰),Li Changrong(李昌荣),Wang Xianghui(王向晖). Journal of Biomedical EngineeringS(生物医学工程学杂志) [J], 2000,17(2):146
    [15]Michiardi A, Aparicio C, Ratner B D et al.Biomaterials[J],2007, 28(4):586
    [16]Kaelble D H, Moaeanin J. Polymer[J], 1977, 18(5):475
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

[Xu Lin, Ding Jianning, Xu Xiaojing, HeYuanqing, Lei Xiaochun. Blood Compatibility of TiO2-HA Bioceramic Coating on Titanium[J]. Rare Metal Materials and Engineering,2017,46(5):1299~1304.]
DOI:[doi]

Copy
Article Metrics
  • Abstract:1633
  • PDF: 1276
  • HTML: 161
  • Cited by: 0
History
  • Received:January 15,2015
  • Revised:March 06,2015
  • Adopted:May 13,2015
  • Online: September 27,2017