CP-Ti在含氟离子硝酸中电化学腐蚀行为
基金项目:

陕西省重点研发计划项目(2017ZDXM-GY-044)


Electrochemical Corrosion Behavior of CP-Ti in Nitric Acid Containing Fluoride Ions
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [1]
  • |
  • 相似文献
  • |
  • 引证文献
  • | |
  • 文章评论
    摘要:

    采用开路电位(OCP)、动电位极化曲线(PPC)、电化学阻抗谱(EIS) 3种电化学测试手段对工业纯钛(CP-Ti)在含氟离子硝酸溶液中的电化学腐蚀行为进行研究。结果表明:随着硝酸溶液中氟离子浓度的增加,CP-Ti耐蚀性变差;影响CP-Ti耐蚀性转变的临界氟离子浓度为1. 25 mmol/L;氟离子与CP-Ti表面的氧化膜发生反应,致使均匀、致密的氧化膜溶解转变为多孔膜,降低了CP-Ti的耐蚀性。

    Abstract:

    The electrochemical corrosion behavior of CP-Ti in nitric acid solution containing fluoride ions was studied by electrochemical measurements including open circuit potential( OCP),potentiodynamic polarization curves( PPC)and electrochemical impedance spectroscopy( EIS). The results show that the corrosion resistance of CP-Ti decreases with the increase of fluoride ion concentration,and the critical value of fluoride ion concentration affecting the corrosion resistance of CP-Ti is 1. 25 mmol/L. The reaction between fluoride ion and protective oxide film on CP-Ti surface results in the dissolution of homogeneous and dense oxide film into porous film,which deteriorates the corrosion resistance of CP-Ti.

    参考文献
    [4]黄淑梅,陈伟东,王运锋,等.中国氧氯化锆产业现状及发展对策[J].钛工业进展,2014,31(2):1-7.
    相似文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

. CP-Ti在含氟离子硝酸中电化学腐蚀行为[J].钛工业进展,2019,36(1):30-34.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 在线发布日期: 2019-06-03
  • 出版日期: 2019-02-25